Instructions - Parts
Electric Heated
Hose Power Supply
Kit 256876
313258C
EN
Monitor and control fluid temperature in a low voltage heated hose for XM
plural-component sprayers feeding a remote XM mix manifold.
Not for use in explosive atmospheres.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
the kit and maximum working pressures.
ti20972a
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where
applicable.
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
•
•
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
•
•
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
•
•
•
•
Ground all equipment in the work area. See Grounding instructions.
Use only grounded hoses.
Hold gun firmly to side of grounded pail when triggering into pail.
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS forms from distributor or retailer.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
•
•
•
•
•
•
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
ELECTRIC SHOCK HAZARD
Improper grounding, setup, or usage of the system can cause electric shock.
•
Turn off and disconnect power at main switch before disconnecting any cables and before servicing
equipment.
•
•
Connect only to grounded power source.
All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
313258C
3
Warnings
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just
a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
•
•
•
•
•
•
Do not point gun at anyone or at any part of the body.
Do not put your hand over the spray tip.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Do not spray without tip guard and trigger guard installed.
Engage trigger lock when not spraying.
Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning,
checking, or servicing equipment.
4
313258C
Installation
Installation
Setup
1. Insert rubber feet of control box through holes in
plate (4). Mount control box (2) on the XM frame
using plate (4), bolts (7), and nuts (6).
Installing this equipment requires access to parts that
may cause electric shock or other serious injury if
work is not performed properly. Have a qualified elec-
trician connect power and ground to power switch ter-
sure your installation complies with all national, state,
and local safety and fire codes.
2
7
7
Connect Power Cable Wires
1. Turn off power to junction box (J).
2. Replace the supplied liquid-tight conduit connector
(C) with cord restraint fitting (8). Thread the three
wires of the power cord to the opposite side of the
cabinet for connection to the power inlet at the main
disconnect (D). See FIG. 3.
4
6
ti20973a
3. Secure the service wires to 1L1 and 3L2 using a #2
Phillips or Pozidriv M3,5 Form 2 screwdriver.
Tighten to 7 in-lb (0.8 N•m).
FIG. 1: Mount Control Box
2. Place bracket (5) on top of the control box (2) and
mount to the XM frame using screws (7) and nuts
(6).
4. Connect the external ground bond wire (Green or
Green/Yellow) to the protective earth lug (PE).
Secure with a 3/8 or 7/16 flat-bladed screwdriver.
Tighten to 35 in-lb (4 N•m).
6
C
1L1
D
2
5
7
3L2
3L2
PE
ti19942a
FIG. 3: Main Disconnect Electrical Connections
ti20974a
NOTICE
FIG. 2: Mount Plate
Route power cable (3) to avoid interference with
313258C
5
Setup
5. Route power cable (3) up through cord grip (JC).
7. Connect power wiring from 1L1 and 3L2 to terminal
blocks 1 and 3 in TB1.
6. Connect other end of grounding wire to grounding
lug nut (X) inside junction box (J).
TB1
J
X
C
JC
3
D
3L2
3L2
1L1
C
2
PE
ti20975a
FIG. 4: Heat Control Box Cable Connections
6
313258C
Setup
8. Set transformer wire taps in hose heat control box
(2). See manual 3A2980 to verify tap wire connec-
tion.
Connect 24M943 FTS and Power
Wires
9. Install adapters (16) in dosing valve blocks and use
fittings (14, 15, 17, or 18) to connect heated hose
(1) fluid inlets.
NOTICE
Do not coil hose tighter than the minimum bend
radius of 3 ft (0.9 m). Do not subject hose to exces-
sive weight, impact, or other abuse.
1. Carefully extend FTS probe (H) into the hose sec-
tion from the hose heat control. Do not bend or kink
probe. Insert probe in major volume resin side
on systems which are not 1:1 mix ratio.
2. Connect FTS (9) to fittings (12) on remote XM mix
3. Connect fitting (23) to FTS coupler (9a) and fitting
(19 or 20). Connect fittings (21 or 22) to FTS sensor
(9c). Connect fluid hoses to FTS (9).
16
16
14,
15,
17,
14,
15,
17,
4. Install one connector (D) between wires. Refer to
Connect Heated Hoses in manual 309572 for
instructions.
or 18
or 18
WLꢀꢁꢂꢃꢄD
5. Connect hose assembly cable (F) to FTS cable (R).
Slide insulator sleeves (S) over connection. Leave
slack (G) in cables as stress relief, to prevent cable
failure.
FIG. 5: Dosing Valves
NOTE:
To connect additional hoses see manual 309572.
To XM Mix Manifold
S
10. Install fittings (12) in remote XM mix manifold.
9a
R
F
S
G
9c
H
12
23
9a
D
ti2684d
To XM sprayer
WLꢀꢁꢂꢃꢂD
FIG. 7: 261670 FTS Kit
12
9c
21 or 22
6. Connect two black power wires from the hose heat
control box (2) to heated hose (1). Refer to Connect
Fluid Hose in manual 3A2980 for instructions.
19 or 20
FIG. 6: XM Mix Manifold
7. Connect FTS cable from control box (2) to FTS
cable connection of first length of heated hose from
XM sprayer. See illustrations on page 9.
313258C
7
Parts
Parts
6
2
8
5
16
6
14,
15,
17,
14,
15,
7
17,
or 18
or 18
23
12
7
9a
6
9
4
9c
12
6
21 or 22
19 or 20
WLꢀꢅꢆꢇꢃE
Qty
.
Qty
Ref. Part
Description
Ref. Part
Description
.
12
13
14
15
158491 NIPPLE; 1/2 X 1/2 npt
159239 NIPPLE; 1/2 x 3/8 npt
122406 ADAPTER, (-5) 1/2-20 JIC x 3/8 npt
117832 ADAPTER, (-6) 9/16-18 JIC x 3/8
npt
100081 BUSHING, pipe; 1/2 x 3/8
117833 ADAPTER; (-8) JIC x 3/8 npt
116765 ADAPTER, (-10) JIC x 3/8 npt
117595 UNION, 1/4 npt x (-5) swivel
117506 UNION, 1/4 npt x (-6) swivel
126329 UNION, 1/2 npt x (-8) swivel
126330 UNION, 1/2 npt x (-10) swivel
100206 BUSHING, 1/2 x 1/4 npt
2
1
1
1
1✖
---
HOSE SET, heated, order sepa-
rately; see manual 309572
1
2
24P616 KIT, heated hose control; see man-
ual 3A2980
15T969 CABLE, hose heat, 3 cond, 12GA;
see manual 3A2980
256196 PLATE, mounting to XM
256326 BRACKET, control bo to XMx,
heated hose
112958 NUT, HEX, flanged
112395 SCREW, cap, flng hd
116171 BUSHING, strain relief
24M943 KIT, fluid temperature sensor, cou-
pler: see manual 309572
1
1
3✖
16
17
18
19
20
21
22
23
1
1
1
1
1
1
1
1
4
5
1
1
6
7
8
9
2
6
1
1
✖ Not shown.
9a
9b
9c
16N637 COUPLER, 1/2 fbe; 3.5 in.
24H320 HOSE, air; 3.75 in.
--- Not available for purchase.
---
SENSOR 1/2 in. FTS
313258C
9
Technical Data
Technical Data
Hose Heat Control 24P616
Input Power Requirements. . . . . . . . . . . . . . . . . . . . . . . . 230 Vac, 1 phase, 50/60 Hz, 15A
Output Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-62 Vac, 45 A
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 lb (39 kg)
Heated Hose 248908, 248907, 262727, 262728, 262730
Maximum working fluid pressure . . . . . . . . . . . . . . . . . . . 5000 psi (34.5 MPa, 345 bar)
Maximum air working pressure . . . . . . . . . . . . . . . . . . . . 130 psi (0.9 MPa, 9 bar)
Maximum hose operating temperature. . . . . . . . . . . . . . . 180°F (82°C)
FTS Sensor Kit 24M943
Maximum working fluid pressure . . . . . . . . . . . . . . . . . . . 5000 psi (34.5 MPa, 345 bar)
Fluid Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 in npt(f) both ends
313258C
11
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 313258
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2009, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Revision C, April 2014
|